Problem
This article provides guidance for re-installing the G360 Access Control Service on a PC used to control gates, doors, or turnstiles. This should only be used if the system has previously been commissioned, tested, and verified as operational. For new installations or adding entry points, contact your Regional Sales Manager.
Resolution
Prerequisites
- Ensure you have local administrator privileges on the PC.
- Download the required software from the provided source.
Config File Preparation
- Confirm the following folders exist. If not, create them:
C:\Program Files (x86)\MRM Software\AccessControlC:\Install
- Move the downloaded software to
C:\Installand rename the folder toAccess. - Create a backup copy of
AccessControlServiceInstaller.ini. - Open
AccessControlServiceInstaller.iniusing Notepad++ or a similar editor. The default config includes:;Installation section defines installation directory [Installation] ServiceName=AccessControl.Service ServiceDisplayName=Gladstone Access Control Service ;Make sure the path exists InstallDir=C:\Program Files (x86)\MRM Software\AccessControl [ExternalURL] ;Web Api Website Url WebApiUrl=http://localhost/Gladstone360/Access/Api CheckApiIsValidAtInstall=True [Config] ;Install for the following Site ID Site= - Adjust the following sections:
- Update
WebApiUrlto use your live URL, for example:WebApiUrl=https://yourdomain.gs-signature.cloud/Gladstone360/Access/Api - Set the
Sitevalue to your site prefix, e.g.,Site=HOfor Head Office. Site prefix can be obtained from Plus2 or Gladstone360.
- Update
- Save the file and re-open it to ensure your changes have been saved.
- Confirm the following folders exist. If not, create them:
Running the Installer
- Open Command Prompt as Administrator.
- Navigate to
C:\Install\Access. - Type
dirto ensure you seeAccessControlServiceInstaller.iniand.msi. - Run the installer with the following command:
msiexec.exe /i AccessControlServiceInstaller.msi /lei install_1.txt - A progress bar will appear. Look for the "INSTALLATION SUCCESSFUL!" message upon completion.
- If there are any errors, review
install_1.txtfor the word "error" and check:- Command Prompt is running as Administrator.
- Required folders are created.
- WebApiURL and Site prefix are correct.
- If re-running the installer, increment the number in the log file name (
install_2.txt, etc.) for tracking.
Post Installation Checks
- Open the Windows Services panel and verify that "Gladstone Access Control Service" is running.
- If running, stop the service to allow configuration changes.
Service Config File Configuration
- Go to
C:\Program Files (x86)\MRM Software\AccessControland locateAccessControlHardwareService.exe.config. Make a backup of this file. - Open
AccessControlHardwareService.exe.configwith Notepad++ or similar. - Find the
AppSettingssection. By default, COM port settings are commented out (<!-- ... -->). Uncomment the relevant line(s) for the required COM port. - Use Device Manager to confirm which COM port is connected to the hardware.
- Set the COM port value as needed. The configuration line format is:
Key=[COM port] Value=[7 comma separated values]- Adjust only the required sections in bold:
- BaudRate (typically 9600)
- DataBits (usually 8)
- StopBits (usually 1)
- handshake (typically None)
- Parity (typically None)
- NumberOfBoards (number of connected hardware ID boards, including main and secondary boards)
- SwipeReaderPrefix (as configured in GMC or Plus2)
- Adjust only the required sections in bold:
- Save the file.
- Start the "Gladstone Access Control Service" to apply changes.
- Review Windows application event logs to confirm the service has started successfully (look for com port activity and correct board/software versions).
- Go to
Testing the G360 Access Module
- Go to the main G360 URL and log in.
- Open the Access module, making sure the correct Site and Screen layout are selected.
- Using a membership card, fob, or QR code, swipe at each entry point and ensure that data is reported back.
Notes
- Only use this procedure for re-installation purposes where the system has already been commissioned and tested.
- For new access control setups or adding more entry points, contact your Regional Sales Manager.